CCEER 00-9: Shake Table Testing of 1960's Two Column Bent with Hinges Bases

Loading...
Thumbnail Image

Authors

Moore, Jennifer
Sanders, David H.
Saiidi, Mehdi S.

Issue Date

2000-12-01

Type

Report

Language

Keywords

CCEER

Research Projects

Organizational Units

Journal Issue

Alternative Title

Abstract

This report describes the testing of a 0.3-scale as-build bent based on the average properties of six bridge bents in California. The prototype bents are characterized by a hinge detail at the bottom of the columns with insufficient development length of the hinge bars and minimal confinement along the length of the columns. The model bent was dynamically tested using a series of increasing amplitudes of the Sylmar earthquake acceleration record, to a displacement ductility of 4.3. Observation of the tested model showed limited spalling of the columns and minimal cracking of the beam. Analytical analysis predicted the lateral load capacity of the bent, when the moment capacity of the hinge and bond slip were included in the dynamic model. This test concluded that the prototype bridge bents would perform as desired in a seismic event, and no seismic retrofit is necessary for areas of low seismicity.