City of Fernley, EWWTP Proposed Improvements
Loading...
Authors
Kaiser, Ashley
Mital, Jenny
Issue Date
2013
Type
Thesis
Language
en_US
Keywords
Alternative Title
Abstract
The following report describes the proposed redesign of the East Wastewater Treatment Facility (EWWTP) for the City of Fernley, Nevada. The existing facility is designed for a flow of 3.4 MGD, but by the end of the 30-year design period in 2045, the projected maximum flow will rise to 5.45 MGD. The goal of this design is to modify and expand upon the existing treatment plant to allow the City of Fernley to treat the 30-year flow and produce an effluent of sufficient quality to use as irrigation water. Based on the evaluation of existing facilities and typical design parameters for small wastewater treatment facilities, a conventional design including grit removal, biological treatment, nitrification, secondary clarification, filtration, and disinfection is proposed. Design information for the addition of optional primary clarifiers is also included.
Description
The University of Nevada, Reno Libraries will promptly respond to removal requests related to content that violates intellectual property laws, data protections, or has been uploaded without creator consent. Takedown notices should be directed to our ScholarWolf team (scholarwolf@library.unr.edu) with information about the object, including its full URL and the nature of your complaint.
Citation
Publisher
License
In Copyright(All Rights Reserved)